Ultrasonic algae and biofouling controller for pond and lakes
Introduction of Ultrasonic algae used for ponds
Ultra-sonic wave is widely recognized and proven method of removing alga, degrading organic pollutant of water. It has advantages over other traditional alga-removing and inhibiting methods such as handmade remove alga. Ultrasonic algae
Ultra-sonic wave device is consisted of a launcher, float device, wire and control box.
Working Principle
Principle of Operation
“Cavitation effect” will happen if ultra-sonic energy is transmitted in liquid or water.
The ultra-sonic wave device system releases ultra sonic wave, which creates a sudden hotpot, with high temperature and high pressure, after a series of power cycle, like oscillation, expansion, compression and collapse. Several seconds later, the hotpot cooled instantly, with a strong shock wave, which generates an extreme physical environment for organism and alga. Alga’s cell membrane broke down at this specific frequency of ultra-sonic wave, and finally decline and disappear.
Application
Ultrasonic algae used for ponds Application fields:
.Plants for potable and waste water treatment
.Sedimentation tanks
.Cooling towers
.Ponds
.Lakes
.Outdoor swimming pools
.Irrigation systems
Feature
Ultrasonic algae used for ponds Features:
Good ability in degrading microcystins, no second pollution
No harmful to human and other aquatic organisms
Good results in alga removal with 15 days
Simple design, low failure rate
Tracking ultra-sonic wave automatically
Alga-removal at all direction
Easy operation, safety use, high efficiency and easy repair
Assembled ultrasonic system for water treatment
|
Description
|
Model
|
Frequancy
|
Power
|
Size (mm)
|
Regular Cable
Length
|
(kHz)
|
(W)
|
Diameter
|
Total Height
|
(m)
|
Transducer
|
GPA-8SH-3020(5*4)-D59.5*110
|
20
|
80
|
59.5
|
110
|
≤15m
|
Transducer
|
GPA-4SH-3825--D76*110
|
25
|
50
|
76
|
110
|
≤15m
|
Transducer
|
GPA-4SS-3528-D59.5*110
|
28
|
50
|
59.5
|
110
|
≤15m
|
Transducer
|
GPA-4SS-5028-D76*110
|
28
|
100
|
76
|
110
|
≤15m
|
Transducer
|
GPA-4SS-3833-D59.5*98
|
33
|
50
|
59.5
|
98
|
≤15m
|
Transducer
|
GPA-4SS-3840-D59.5*85
|
40
|
50
|
59.8
|
85
|
≤15m
|
Transducer
|
GPA-4SS-3840-D59.5*98
|
40
|
50
|
59.5
|
98
|
≤15m
|
Transducer
|
GPA-4SS-3840-D76*110
|
40
|
50
|
76
|
110
|
≤15m
|
Transducer
|
GPA-4SS-3045-D59.5*85
|
45
|
30
|
59.5
|
85
|
≤15m
|
Transducer
|
GPA-4SS-3045-D59.5*98
|
45
|
30
|
59.5
|
98
|
≤15m
|
Transducer
|
GPA-4AS-3050 -D59.5*85
|
50
|
30
|
59.5
|
85
|
≤15m
|
Transducer
|
GPA-4SS-3868-D59.5*98
|
68
|
50
|
59.5
|
98
|
≤15m
|
Transducer
|
GPA-4SS-3880-D59.5*98
|
80
|
50
|
59.5
|
98
|
≤15m
|
Transducer
|
GPA-4SS-38100-D59.5*98
|
100
|
50
|
59.5
|
98
|
≤15m
|
Transducer
|
GPA-4SS-38130-D59.5*98
|
130
|
50
|
59.5
|
98
|
≤15m
|
|
|