4 mhz ultrasonic hifu piezo transducer

Model No.︰

1-10mhz

Brand Name︰

Ginpertec

Country of Origin︰

China

Unit Price︰

-

Minimum Order︰

1 pc

Share on:

Product Description

1 Product applicaiton

Ultrasonic rhytidectomy or medical treatment of cancer. Core components of ultrasonic scalpel and ultrasonic treatment instrument

Product features

The principle of ultrasonic rhytidectomy: through the cluster heat transfer mode of lattice, the skin is circumvent, and under the premise of not cutting the epidermis, the ultrasonic scalpel hairdressing to explore the matrix molecular energy waves that vibrate up to 400-700 million times per second to deep subcutaneous cell damage, and the depth of the hypodermic 1.5-4.5mm left right is directly affected by the deep layer. The fascia, which forms focusing surface in the fascia radio frequency electric field, strongly impacts the dermal tissue and produces the effect of electric field aggregation on the dermal tissue, raising the subcutaneous temperature to 60-75 degrees C, determining the effective heat damage of the heat in the dermal fiber layer, triggering the function of the body to start repairing the regenerated cells and repairing the fascia. The effect of pulling, removing wrinkles and tightening the skin.

The principle of ultrasound focused therapy: the energy of ultrasound in the non treated part of it is not enough to damage the tissue. At the focus of its focus, because of the high sound intensity, the temperature of the tissue rises to 60~100 C by the thermal effect of ultrasound, resulting in protein denaturation and irreversible coagulant necrosis of the tissue cells. Meanwhile, the interstitial fluid, intercellular fluid and the intracellular gas molecules are positive and negative by the cavitation effect of ultrasound. Under the action of phase, bubbles form, and then contract and expand, resulting in the final explosion, resulting in cell damage and necrosis.

High frequency stability

High physical strength

2 Photo show

IMG_20180428_135238_1副本.jpgD50.jpg

3 Technical parameter

 

Description Model Frequency Power Capantiance Out Diameter Focus distance
(Ft) W (pF) mm (mm)
PZT8 Ceramic ¢19.5×0.5-SR18 800Khz 30W 8000±10% 19 18
PZT4 Ceramic ¢95/¢24×8-SR54 250Khz 600 1200±10% 95 54
PZT4 Ceramic ¢75/¢15×8-SR54 250Khz 350 3600±10% 75 54
PZT4 Ceramic ¢75/¢15×8-SR40 250Khz 350 8000±10% 75 40
PZT4 Ceramic ¢70/¢12×8-SR36 250Khz 250 3600±10% 70 36
PZT4 Ceramic ¢50/¢12×8-SR36 250Khz 250 3600±11% 50 36
PZT8 Ceramic ¢20×2-SR20 1MHZ 20 3200±12% 20 20
PZT8 Ceramic ¢24×2-SR22 2MHZ 15 3100±13% 24 22
PZT8 Ceramic ¢35×1-SR30 2MHZ 15 3000±14% 35 30
PZT8 Ceramic ¢35×1-SR33 2MHZ 15 3600±15% 35 33
PZT8 Ceramic ¢38×1-SR38 2MHZ 50 8000±10% 38 38
PZT8 Ceramic ¢23.2×0.7-SR15 3MHZ 10 360±10% 23 15
PZT4 Ceramic ¢23.2×0.64SR20 3MHZ 10 3600±10% 23 20
PZT8 Ceramic ¢20×0.5-SR20 4MHZ 25 6500±10% 20 20
PZT4Ceramic ¢20×0.5-SR18 4MHZ 10 6500±10% 20 18
 

Please contact for more details